More Information
Storelocator
Lupe

Accessory for central inverters

  • Nanocrystalline amorphous glassmetal reduces the no-load losses
  • Significant reduction of operational costs
  • Low standby-costs
Matching products

The transformers excel with their extremely high efficiency factors and minimal no-load losses. Especially the no-load losses of transformers result in significant operational costs of large-scale photovoltaic systems. Transformers, specified and sold by Voltwerk, far exceed the standardised efficiency classes.  

General information600 kVA
(Item no. V2-121-046)
900 kVA
(Item no. V2-121-045)
1250 kVA
(Item no. V2-121-042)
Construction Hermetic design with aluminium coil OS and US
Standards used DIN/IEC 60076 – VDE 0532 T. 6- DIN 42500
Type SBLH15-600/20/0,3-001SBLH15-900/20/0,3-001SBH15-1250/20/0,3-003
Manufacturer Eaglerise Electric & Electronic Co. Ltd / Sunrise Power Transformers GmbH
Electrical data
Rated power 600 kVA900 kVA1250 kVA
Coil design Two-coil Two-coil Two-coil
Primary voltage 20 kV20 kV20 kV
Tappings (no load operation)21,0kV / 20,5 kV / 20 kV / 19,5 kV / 19 kV
Secondary voltage (idling) 300 V (phase to phase) 300 V (phase to phase) 300 V (phase to phase)
Rated current OS coil 17.3 A, US coil 1155 AOS coil 26 A, US coil 1732 AOS coil 36.1 A, US coil 2406 A
Vector group Dyn 11Dyn 11Dyn 11
Efficiency factor (at 100 % load / Cos Φ = 1) *99.10 %99.10 %99.10 %
Efficiency factor (at 75 % load / Cos Φ = 1) *99.40 %99.40 %99.40 %
Rated frequency 50 Hz50 Hz50 Hz
No-load losses Po *320 W400 W580 W
No-load current*0.02 A0.02 A0.03 A
Load losses Pk at 75°C* 6,300 W8,500 W10,000 W
Short circuit voltage Uk at 75°C*5%6%6%
Insulation classAAA
Insulation levelLI 125 AC 50/LI AC 3, at Um = 24 kVLI 125 AC 50/LI AC 3, at Um = 24 kV LI 125 AC 50/LI AC 3, at Um = 24 kV
Maximum starting current* 80 A for 0.2 s120 A for 0.2 s160 A for 0.2 s
Max. installation altitude above sea level ≤ 2,000 m ≤ 2,000 m ≤ 2,000 m
Monitoring / protection
Gas formation / pressure Hermetic full protection block DGPT 2Hermetic full protection block DGPT 2Hermetic full protection block DGPT 2
Temperature measurementPT 100PT 100PT 100
Mechanical data
Dimensions (W x H x D)1,910 x 1,220 x 1,360 mm2,140 x 1,270 x 1,480 mm2,180 x 1,330 x 1,670 mm
Weight 3,010 kg4,060 kg5,570 kg
Castors for longitudinal and transverse drive 4 castors in line with DIN 42561 / 820 mm
Earthing Earthing connections in line with DIN 48088 – M12
Connections OS: Connection type A in line with EN EN 50180 and EN 50181, Connection cone 250 A , US: Terminals in line with DIN 42530
Boiler Hermetically sealed boiler with shafts for cooling and volume compensation
Filling Dried and vented mineral oil
Oil weight 605 kg780 kg990 kg
Cooling / environmental conditions
Cooling typeONANONANONAN
Ambient temperature for rated power ta45 °C45 °C45 °C
Warming oil / coil 50 / 60 K50 / 60 K50 / 60 K
Sound power level*63 dB67 dB65 dB

* Typical values

General informationAuxiliary transformer (Item no. V2-820-008)
Construction Two-coil, Air-cooled transformer
Used standards EN 61558 and VDE 0570
Electrical data
Rated power 14 kVA
Rated voltage – primary side 300 V / 315 V (phase to phase)
Rated voltage – secondary side (idling) 400 V (phase to phase) / 230 V (phase to N)
Vector groupDyn 11
Rated current primary side: 26.9 A / secondary side: 20.2 A
Rated frequency 50 Hz
No-load losses Po*20 W
Load losses Pk at 75°C* 450 W
Insulation class E
Mechanical data
Dimensions (W x H x D)540 x 270 x 400 mm
Weight 115 kg
Connections screw terminal
Cooling / environmental conditions
Cooling typeAir
Ambient temperature for rated power ta45 °C

* Typical values